SPECIFICATIONS:
Features | l 7 kW induction heater to melt alloy with ease. l 10 - 20g samples up to 1600°C l Ø200mm copper flywheel with max. 31 m/s spinning speed l Adjustable distance between crucible and copper wheel. 0~10mm manually l One sample transfer tank is included to prevent samples from exposure to air during sample loading l Two systems can be isolated by an ISO160-K gate valve to prevent cross-contamination during melt-spinning |
Power | l 208- 240VAC, single phase, 50/60 Hz, 7kW for melt-spinning system l 110VAc or 208-240 VAC, single phase, 50/60 Hz, 1.5 kW for the glove box. l Total 8.5 KW. Calbe inclided , but no plug |
Vacuum Chamber | l Stainless steel vacuum chamber: 300 x 300 x 480 mm l Hinged door with quartz observation window (120mm dia.) l Vacuum level: 5e-5 torr within 30 minutes by turbopump l KF40 and ISO100-K vacuum port is built to the chamber. |
Induction Heater | l Induction Heater: l Desktop 7KW Induction Heater, 30 - 80kHz (Standard, non-adjustable frequency) l High Frequency 10 KW Induction Heater, 80 - 200kHz (available at extra cost) l Max. sample load: 5 - 20g (Fe based ) l Max. working temperature: 2000°C l Temperature control of the melt-spinning is not available. l Induction coils with different sizes is available upon request. l Water cooling is required for the induction heater. |
Crucibles | l Two quartz crucibles with an orifice of 0.5 - 1mm dia. are included for materials of melting point < 1200ºC l Customized crucibles made of quartz or BN are available upon request at extra cost l Optional graphite sheath (graphite casing+quartz insulation+larger induction coil in diameter) are also available upon request at extra cost for refractory and low magnetic permeability materials |
Spinning Wheel | l Copper flywheel without water cooling (200 mm Dia. x 40 mm W) l 0 - 31 m/s adjustable l Max. Speed: 3000 RPM l Max. Ribbon width: 12 mm (depended on the nozzle of crucible) l The water-cooling wheel/stainless steel wheel is available upon request with extra cost |
Collection Tube | l Spun and solidified material is collected by the vacuum-sealed drum. l Collector Length: 300 mm |
Glove Box Chamber | l Case Material: Stainless steel 304 with 3 mm thickness l Chamber dimension: 1200 mm L x 740 mm W x 900 mm H l Openable front window panel (tempered glass, 8 mm thick) |
Chamber Condition | l Automatic regeneration for the purification column l Automatic purging function to quickly bring O2 < 100ppm & H2O < 50 ppm before purifying. l Automatic pressure control to keep the pressure at a constant level. l Water <1 ppm (20 °C, 1 atm) l Oxygen <1 ppm (20 °C, 1 atm) |
Leak Rate | l <0.05 vol% / hr (depending on oxygen concentration inside the glove box) |
Antechamber | l Main antechamber Ø360 × 600 L in mm l Second antechamber Ø150 × 220 L in mm |
Working Gas | l Operating gas: Inert gas such as N2, Ar, He l Regenerating gas: 5% H2 blended inert gas |
Gas Purification System | l Automated regeneration process l Automated Water and oxygen purification l Purification cylinder: BASF R3-11 Copper Catalyst and Lindy Molecular Sieve l Pipeline: 304 stainless steel, KF40, and KF25 ports |
Ports & Fittings | l Total three KF40 ports on the back of the glove box |
Gas Filter | l Inlet and outlet HEPA filter can eliminate particle size > 0.3 μm l Carbon and solvent vapor filters are available upon request at the extra cost for flammable vapor |
Pressure Control System | l Automatic pressure control by PLC for the Glove Box Chamber l Pressure range: +/- 12 mbar l Manual pressure control is allowed via a foot pedal |
Purging System | l An automatic purging system allows easy operating and reduces gas consumption |
Control System | l Siemens PLC control system with 7" touchscreen display l Water concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm l Oxygen concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm l Pressure: -12 to 12 mbar with an accuracy of 0.1 mbar l Records for total hours of operation, total regeneration times, time since last regeneration |
Pump | l 240 L/m heavy-duty double stage rotary vane pump is included for glove box. |
Gloves | l A pair of 9 3/4" butyl gloves is included for immediate use |
Optional | l A water-chiller is required but not included l A separate pumping system is required for melt-spinning but not included. |
Warranty | l One-year limited warranty with lifetime support |
During melt-spinning, metal ingots are melted via induction heating and propelled by pressurized inert gas. A thin stream of the melt is cast onto a spinning copper drum. The rapid quenching and solidification process enables the alloy forms amorphous ribbons in a few seconds.
SPECIFICATIONS:
Features | l 7 kW induction heater to melt alloy with ease. l 10 - 20g samples up to 1600°C l Ø200mm copper flywheel with max. 31 m/s spinning speed l Adjustable distance between crucible and copper wheel. 0~10mm manually l One sample transfer tank is included to prevent samples from exposure to air during sample loading l Two systems can be isolated by an ISO160-K gate valve to prevent cross-contamination during melt-spinning |
Power | l 208- 240VAC, single phase, 50/60 Hz, 7kW for melt-spinning system l 110VAc or 208-240 VAC, single phase, 50/60 Hz, 1.5 kW for the glove box. l Total 8.5 KW. Calbe inclided , but no plug |
Vacuum Chamber | l Stainless steel vacuum chamber: 300 x 300 x 480 mm l Hinged door with quartz observation window (120mm dia.) l Vacuum level: 5e-5 torr within 30 minutes by turbopump l KF40 and ISO100-K vacuum port is built to the chamber. |
Induction Heater | l Induction Heater: l Desktop 7KW Induction Heater, 30 - 80kHz (Standard, non-adjustable frequency) l High Frequency 10 KW Induction Heater, 80 - 200kHz (available at extra cost) l Max. sample load: 5 - 20g (Fe based ) l Max. working temperature: 2000°C l Temperature control of the melt-spinning is not available. l Induction coils with different sizes is available upon request. l Water cooling is required for the induction heater. |
Crucibles | l Two quartz crucibles with an orifice of 0.5 - 1mm dia. are included for materials of melting point < 1200ºC l Customized crucibles made of quartz or BN are available upon request at extra cost l Optional graphite sheath (graphite casing+quartz insulation+larger induction coil in diameter) are also available upon request at extra cost for refractory and low magnetic permeability materials |
Spinning Wheel | l Copper flywheel without water cooling (200 mm Dia. x 40 mm W) l 0 - 31 m/s adjustable l Max. Speed: 3000 RPM l Max. Ribbon width: 12 mm (depended on the nozzle of crucible) l The water-cooling wheel/stainless steel wheel is available upon request with extra cost |
Collection Tube | l Spun and solidified material is collected by the vacuum-sealed drum. l Collector Length: 300 mm |
Glove Box Chamber | l Case Material: Stainless steel 304 with 3 mm thickness l Chamber dimension: 1200 mm L x 740 mm W x 900 mm H l Openable front window panel (tempered glass, 8 mm thick) |
Chamber Condition | l Automatic regeneration for the purification column l Automatic purging function to quickly bring O2 < 100ppm & H2O < 50 ppm before purifying. l Automatic pressure control to keep the pressure at a constant level. l Water <1 ppm (20 °C, 1 atm) l Oxygen <1 ppm (20 °C, 1 atm) |
Leak Rate | l <0.05 vol% / hr (depending on oxygen concentration inside the glove box) |
Antechamber | l Main antechamber Ø360 × 600 L in mm l Second antechamber Ø150 × 220 L in mm |
Working Gas | l Operating gas: Inert gas such as N2, Ar, He l Regenerating gas: 5% H2 blended inert gas |
Gas Purification System | l Automated regeneration process l Automated Water and oxygen purification l Purification cylinder: BASF R3-11 Copper Catalyst and Lindy Molecular Sieve l Pipeline: 304 stainless steel, KF40, and KF25 ports |
Ports & Fittings | l Total three KF40 ports on the back of the glove box |
Gas Filter | l Inlet and outlet HEPA filter can eliminate particle size > 0.3 μm l Carbon and solvent vapor filters are available upon request at the extra cost for flammable vapor |
Pressure Control System | l Automatic pressure control by PLC for the Glove Box Chamber l Pressure range: +/- 12 mbar l Manual pressure control is allowed via a foot pedal |
Purging System | l An automatic purging system allows easy operating and reduces gas consumption |
Control System | l Siemens PLC control system with 7" touchscreen display l Water concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm l Oxygen concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm l Pressure: -12 to 12 mbar with an accuracy of 0.1 mbar l Records for total hours of operation, total regeneration times, time since last regeneration |
Pump | l 240 L/m heavy-duty double stage rotary vane pump is included for glove box. |
Gloves | l A pair of 9 3/4" butyl gloves is included for immediate use |
Optional | l A water-chiller is required but not included l A separate pumping system is required for melt-spinning but not included. |
Warranty | l One-year limited warranty with lifetime support |
During melt-spinning, metal ingots are melted via induction heating and propelled by pressurized inert gas. A thin stream of the melt is cast onto a spinning copper drum. The rapid quenching and solidification process enables the alloy forms amorphous ribbons in a few seconds.