This product is a stainless steel glove box with the hinged type of front door designed for much easy loading and unloading device into the glove-box. The purification cylinder is made of BASF R3-11 Copper Catalyst and Lindy Molecular Sieve in order to achieve a low water and oxygen concentration of lower than 1 ppm, such that experiments can be conducted in a ultra-clean and highly purified gas environment. It is integrated with vapor pressure control system, purity control system, automatic gas purity regeneration control system, and system data log recording. It is widely used in preparing nanomaterials, Li-ion battery materials, catalysts, and metallorganics and perfectly fitted for Lithium-sulfur and lithium metal battery research.
Pledge: genuine guarantee,speed refund,gift insurance,seven days no reason to return
Product Description
This glove box can be customized according to different application scenarios. For example, in the field of electronic manufacturing, glove boxes can be equipped with anti-static devices to prevent static electricity from damaging electronic components. In the pharmaceutical industry, glove boxes can meet strict aseptic requirements and use special disinfection and purification measures. In the field of scientific research, glove boxes can adjust their internal spatial layout and purification system parameters according to specific experimental needs.
With the continuous advancement of technology, the performance of glove boxes is also constantly improving. In the future, we can expect more efficient purification systems, more intelligent control functions, and more user-friendly designs. These improvements will enable glove boxes to be widely used in more fields, providing strong support for technological innovation and industrial development.
Product Parameters
Working Voltage | 220V AC,50/60HZ |
Max.Power Consumption | 6KW |
Glove Box Chamber | Case Material: Stainless steel Chamber dimension: 1200 mm L x 740 mm W x 900 mm H Openable front window panel (tempered glass, 8 mm thick) Hinged-type door for easy load of devices inside the glove box
|
Chamber Condition | Water concentration: <1 ppm (20°C, 1 atm) Oxygen concentration: <1 ppm (20°C, 1 atm)
|
Working Gas | Operating gas: Inert gas such as N2, Ar, He |
Filter System | Organic Solvent Filter System filled with replaceable activated carbon |
Gas Purification System | Automated Regeneration Process capacity: 1.5KG Pipeline: 304 stainless steel, KF40, and KF25 ports
|
Leak Rate | <0.05 vol% / hr (depending on oxygen concentration inside the glove box)
|
Pressure Control System | Automatic pressure control by PLC for the Glove Box Chamber Pressure Range: +/- 12mbar Manual pressure control is allowed via a foot pedal
|
Air-lock Chamber | Antechamber Dimensions: 360mm(Dia.) x 600mm(L) Small Chamber Dimensions (for tools): 150 mm(Dia.) x 300m
|
Purging System | Automatic Purging System allows easy operating and reduces gas consumption |
Control system | Siemens PLC control system with 6" touch screen display |
Ports & Fittings | Total seven KF40 ports on the back of the glove box
|
Data | Automatic system data logging |
Gloves | A pair of 9 3/4" butyl glove is included
|
Lighting | Built-in fluorescent lamp
|
Product Dimensions | 2000mm(L) x 1000mm(W) x 1900mm(H) (91" x 59" x 75") |
Shipping Dimension | 86"L x 45" Wx 91"H |
Shipping Weight | 640 kg (1400 lbs)
|
Warranty | One Year limited warranty with lifetime support Rusting and damage due to improper storage condition or maintenance are not covered by warranty Gloves are consumable items and are NOT covered by warranty The Oxygen Sensor is a consumable component NOT covered by warranty. Storing the sensor to ensure maximum longevity when not used. |
Application Notes & Warnings | The interconnections between the glove box chamber and the gas purification system must be unimpeded during the purification cycles. The O2 removal rate is largely dependent on the type of purging gas used. For a faster chamber purging process, Nitrogen is preferred over Argon due to its lighter mass Regularly perform regeneration to maintain optimum purification efficiency. The O2 sensor is consumable and its expected lifespan is around one year. We supply a replacement O2 sensor.
|
Note:Glove box can be customized according to customers’ requirements.
Product Description
This glove box can be customized according to different application scenarios. For example, in the field of electronic manufacturing, glove boxes can be equipped with anti-static devices to prevent static electricity from damaging electronic components. In the pharmaceutical industry, glove boxes can meet strict aseptic requirements and use special disinfection and purification measures. In the field of scientific research, glove boxes can adjust their internal spatial layout and purification system parameters according to specific experimental needs.
With the continuous advancement of technology, the performance of glove boxes is also constantly improving. In the future, we can expect more efficient purification systems, more intelligent control functions, and more user-friendly designs. These improvements will enable glove boxes to be widely used in more fields, providing strong support for technological innovation and industrial development.
Product Parameters
Working Voltage | 220V AC,50/60HZ |
Max.Power Consumption | 6KW |
Glove Box Chamber | Case Material: Stainless steel Chamber dimension: 1200 mm L x 740 mm W x 900 mm H Openable front window panel (tempered glass, 8 mm thick) Hinged-type door for easy load of devices inside the glove box
|
Chamber Condition | Water concentration: <1 ppm (20°C, 1 atm) Oxygen concentration: <1 ppm (20°C, 1 atm)
|
Working Gas | Operating gas: Inert gas such as N2, Ar, He |
Filter System | Organic Solvent Filter System filled with replaceable activated carbon |
Gas Purification System | Automated Regeneration Process capacity: 1.5KG Pipeline: 304 stainless steel, KF40, and KF25 ports
|
Leak Rate | <0.05 vol% / hr (depending on oxygen concentration inside the glove box)
|
Pressure Control System | Automatic pressure control by PLC for the Glove Box Chamber Pressure Range: +/- 12mbar Manual pressure control is allowed via a foot pedal
|
Air-lock Chamber | Antechamber Dimensions: 360mm(Dia.) x 600mm(L) Small Chamber Dimensions (for tools): 150 mm(Dia.) x 300m
|
Purging System | Automatic Purging System allows easy operating and reduces gas consumption |
Control system | Siemens PLC control system with 6" touch screen display |
Ports & Fittings | Total seven KF40 ports on the back of the glove box
|
Data | Automatic system data logging |
Gloves | A pair of 9 3/4" butyl glove is included
|
Lighting | Built-in fluorescent lamp
|
Product Dimensions | 2000mm(L) x 1000mm(W) x 1900mm(H) (91" x 59" x 75") |
Shipping Dimension | 86"L x 45" Wx 91"H |
Shipping Weight | 640 kg (1400 lbs)
|
Warranty | One Year limited warranty with lifetime support Rusting and damage due to improper storage condition or maintenance are not covered by warranty Gloves are consumable items and are NOT covered by warranty The Oxygen Sensor is a consumable component NOT covered by warranty. Storing the sensor to ensure maximum longevity when not used. |
Application Notes & Warnings | The interconnections between the glove box chamber and the gas purification system must be unimpeded during the purification cycles. The O2 removal rate is largely dependent on the type of purging gas used. For a faster chamber purging process, Nitrogen is preferred over Argon due to its lighter mass Regularly perform regeneration to maintain optimum purification efficiency. The O2 sensor is consumable and its expected lifespan is around one year. We supply a replacement O2 sensor.
|
Note:Glove box can be customized according to customers’ requirements.