1500 ℃ Max Hi-Throughput 4 Channel Box Furnace(120*120*120mm) there are Consists of four small box furnaces. Each module is independently temperature controlled, with a maximum temperature of 1500℃ Can simultaneously accommodate four samples for heat treatment at different temperatures High-purity alumina fiber chamber coated with alumina layer to enhance heating efficiency and extend the lifespan Double-shell structure with a built-in air cooling system for surface cooling

  • Price
    0
total sales0
evaluate0
Qty
- +

Pledge: genuine guarantee,speed refund,gift insurance,seven days no reason to return

  • Product Details
  • 1500 ℃ Max Hi-Throughput 4 Channel Box Furnace(120*120*120mm) 


    The STA-1500X-MGI-4 is a four-channel box furnace with a chamber size of 120*120*120mm. It can be used for high-throughput processing of multiple samples with a maximum temperature reaching 1500℃. Each heating module has an independent temperature control system, allowing simultaneous processing of four samples at different temperatures. This equipment has a small footprint, and low energy consumption, making it an ideal product for universities, research institutions, and enterprises involved in high-temperature sintering and quality testing. Suitable for exploring phase diagrams of new-generation materials.

    Furnace Structure

    Consists of four small box furnaces.

    Each module is independently temperature controlled, with a maximum temperature of 1500℃

    Can simultaneously accommodate four samples for heat treatment at different temperatures

    High-purity alumina fiber chamber coated with alumina layer to enhance heating efficiency and extend the lifespan

    Double-shell structure with a built-in air cooling system for surface cooling

    Specifications

    Voltage: AC220V 50/60HZ, (two-phase 220V)

    Power: 10KW

    Heating rate: ≤10℃/min

    Chamber size: 120*120*120mm

    Heating element: Silicon carbide

    Thermocouples

    S-type 

    Working Temp. 

    Continuous Working Temperature 1300° C

    Maximum Working Temperature 1400°C (< 30 mins)

    Maximum 1500°C upon request at extra cost

    Temperature Control

    Touchscreen temperature control module

    Four independent temperature control channels enable simultaneous one-touch temperature control

    PID automatic temperature control system

    Intelligent 50-stage programmable control

    Default DB9 PC communication connection port

    Temperature control accuracy: ±1℃. (optional European temperature control accuracy up to ±0.1℃)

    Laptop, software  (Optional)
        

     

    Brand new laptop with Microsoft Windows 10 and Microsoft Office 2013 (30 days free trial)

    Labview-Based Temperature Control System (EQ-MTS01) enables users to edit temperature profiles, manage heat-treatment recipes, and record and plot data for STA furnaces.

    Dimension 

    900*600*1400mm

    Weight

    ~ 110 Kg

    Warranty

    One year limited with lifetime support --- including all electronic and mechanical parts only.  Damaged parts caused by misuse: such as rusted parts from inadequate storage and broken parts by the user are not covered by the standard warranty.

    We reserve the right to upgrade the furnace structure for better performance without notice

    Warning &
    Application note

    STA does not recommend customers to use flammable, explosive, or toxic gases(materials). If necessary due to the customers' needs,  it is the customer who must take responsibility for relevant protection and explosion-proof measures. STA is not responsible for issues arising from the use of flammable, explosive, or toxic gases(materials)

    The equipment should operate on an independent power source, with a voltage range requirement within ±8%. It should not share the power grid with equipment generating high magnetic fields like medium and high-frequency devices. It should not be in the same room as such equipment. If unavoidable, conduct harmonic detection and treatment on the power grid and implement electromagnetic isolation for the equipment.

    Keep the equipment away from areas prone to liquid splashing

    Keep the equipment away from areas with magnetic or conductive powders

    Insulation and heating elements are consumables. Cracks in insulation material during sintering are normal; they can be repaired using patching agents. Heating elements are also consumables. If the electric furnace cannot reach the working temperature or shows a significant slowdown in heating after prolonged use, contact the manufacturer to determine if replacement is necessary

    There might be temperature fluctuations during low-temperature(below 300) operation

    DO NOT open the furnace at temperatures exceeding 500


    1500 ℃ Max Hi-Throughput 4 Channel Box Furnace(120*120*120mm) 


    The STA-1500X-MGI-4 is a four-channel box furnace with a chamber size of 120*120*120mm. It can be used for high-throughput processing of multiple samples with a maximum temperature reaching 1500℃. Each heating module has an independent temperature control system, allowing simultaneous processing of four samples at different temperatures. This equipment has a small footprint, and low energy consumption, making it an ideal product for universities, research institutions, and enterprises involved in high-temperature sintering and quality testing. Suitable for exploring phase diagrams of new-generation materials.

    Furnace Structure

    Consists of four small box furnaces.

    Each module is independently temperature controlled, with a maximum temperature of 1500℃

    Can simultaneously accommodate four samples for heat treatment at different temperatures

    High-purity alumina fiber chamber coated with alumina layer to enhance heating efficiency and extend the lifespan

    Double-shell structure with a built-in air cooling system for surface cooling

    Specifications

    Voltage: AC220V 50/60HZ, (two-phase 220V)

    Power: 10KW

    Heating rate: ≤10℃/min

    Chamber size: 120*120*120mm

    Heating element: Silicon carbide

    Thermocouples

    S-type 

    Working Temp. 

    Continuous Working Temperature 1300° C

    Maximum Working Temperature 1400°C (< 30 mins)

    Maximum 1500°C upon request at extra cost

    Temperature Control

    Touchscreen temperature control module

    Four independent temperature control channels enable simultaneous one-touch temperature control

    PID automatic temperature control system

    Intelligent 50-stage programmable control

    Default DB9 PC communication connection port

    Temperature control accuracy: ±1℃. (optional European temperature control accuracy up to ±0.1℃)

    Laptop, software  (Optional)
        

     

    Brand new laptop with Microsoft Windows 10 and Microsoft Office 2013 (30 days free trial)

    Labview-Based Temperature Control System (EQ-MTS01) enables users to edit temperature profiles, manage heat-treatment recipes, and record and plot data for STA furnaces.

    Dimension 

    900*600*1400mm

    Weight

    ~ 110 Kg

    Warranty

    One year limited with lifetime support --- including all electronic and mechanical parts only.  Damaged parts caused by misuse: such as rusted parts from inadequate storage and broken parts by the user are not covered by the standard warranty.

    We reserve the right to upgrade the furnace structure for better performance without notice

    Warning &
    Application note

    STA does not recommend customers to use flammable, explosive, or toxic gases(materials). If necessary due to the customers' needs,  it is the customer who must take responsibility for relevant protection and explosion-proof measures. STA is not responsible for issues arising from the use of flammable, explosive, or toxic gases(materials)

    The equipment should operate on an independent power source, with a voltage range requirement within ±8%. It should not share the power grid with equipment generating high magnetic fields like medium and high-frequency devices. It should not be in the same room as such equipment. If unavoidable, conduct harmonic detection and treatment on the power grid and implement electromagnetic isolation for the equipment.

    Keep the equipment away from areas prone to liquid splashing

    Keep the equipment away from areas with magnetic or conductive powders

    Insulation and heating elements are consumables. Cracks in insulation material during sintering are normal; they can be repaired using patching agents. Heating elements are also consumables. If the electric furnace cannot reach the working temperature or shows a significant slowdown in heating after prolonged use, contact the manufacturer to determine if replacement is necessary

    There might be temperature fluctuations during low-temperature(below 300) operation

    DO NOT open the furnace at temperatures exceeding 500