ZHENGZHOU HENGTONG FURNACE CO,. LTD
Three Zone Hydrogen Gas Tube Furnace with alloy Tube and Hydrogen Detector
  • Three Zone Hydrogen Gas Tube Furnace with alloy Tube and Hydrogen Detector
  • Three Zone Hydrogen Gas Tube Furnace with alloy Tube and Hydrogen Detector
  • Three Zone Hydrogen Gas Tube Furnace with alloy Tube and Hydrogen Detector
  • Three Zone Hydrogen Gas Tube Furnace with alloy Tube and Hydrogen Detector
0 1 2 3

Three Zone Hydrogen Gas Tube Furnace with alloy Tube and Hydrogen Detector

Three Zone Tube Furnace is a safe hydrogen tube furnace. The processing tube is made of high-quality Ni-based superalloy which never cracks and is broken at flowing Hydrogen gas. Two hydrogen detectors are included which will shut down the Hydrogen gas generator and gas inlet valve immediately once detecting hydrogen gas leaking. The Hydrogen Gas tube furnace is designed for processing material under hydrogen gas up to 1200°C safely. The precision temperature controller is 30 segment programmable.

  • Price
    0
total sales0
evaluate0
Qty
- +

Pledge: genuine guarantee,speed refund,gift insurance,seven days no reason to return

  • Product Details
  • HTTF-1200-III-H2 Three Zone Tube Furnace is a safe hydrogen tube furnace. The processing tube is made of high-quality Ni-based superalloy which never cracks and is broken at flowing Hydrogen gas. Two hydrogen detectors are included which will shut down the Hydrogen gas generator and gas inlet valve immediately once detecting hydrogen gas leaking. The Hydrogen Gas tube furnace is designed for processing material under hydrogen gas up to 1200°C safely. The precision temperature controller is 30 segment programmable.

     

    Gas Furnace Structure

    Double layer steel casing with air cooling to keep furnace surface temperature lower than 80°C

    High purity fibrous alumina insulation for Max. energy saving

    Hydrogen detector and solenoid valve are included for safe operation

    4 alumina tube blocks (alumina coated on the surface) are included, to be put inside of the tube before operating the equipment in order to avoid heat radiation

    Power

    11 KW Max. (50A breaker required)

    Voltage

    AC 208-240 Single Phase, 50/60 Hz

    Working Temperature

    Furnace continuous temperature: 1400°C (Alumina tube must be used under this temperature)

    Tube Max. working temperature: 1250°C (< 0.5 hours, superalloy tube can't be used over this temperature)

    Tube continuous temperature: 1200°C (Quartz liner inside of the superalloy tube can't be used over this temperature)

    Max. Heating Rate

    10°C/min ( 5°C/min is recommended)

    Processing Tube

    Material: Nickel-based super-alloy seamless tube  ( Cr20NI25Al15

    Tube Size: OD 80mm x ID 72mm x Length 1200mm

    Temperature  1250°C, the tube can withstand pressure  0.1 Mpa

    Temperature  1200°C, the tube can withstand pressure  0.3 Mpa

    Temperature  1100°C, the tube can withstand pressure  1 Mpa

    Temperature  1000°C, the tube can withstand pressure  1.5 Mpa

    Temperature  900°C, the tube can withstand pressure  3 Mpa

    Temperature  800°C, the tube can withstand pressure  5 Mpa

    Heating Zone length

    Three-zone total length: 600mm

    Zone 1: 180mm, Zone 2: 180mm, Zone 3: 180mm

    Constant temperature zone: 260mm ± 3°C (set the same temperature for all 3 zones)

    Temperature controller

    PID automatic control with 30 segments programmable 

    Automatic over-temperature and thermal broken protection

    RS485 Communications Port

    Advanced Temperature Control (Optional)

    MTS02-Y Temperature control software kit (for YD518P series controllers) + 15" laptop package is available at the options bar.

    You may upgrade the controller to the Eurotherm 3004 with +/- 0.1 accuracy, which is compatible with LabVIEW. This package includes a Eurotherm 3004 programmer, and a communication cable (RS485 - USB).

    Flanges and Gas Inlet

    A set of SS304 flanges are included, KF-25 gas outlet port

    Vacuum level: 10-2 torr using a mechanical pump, 10-5 torr using a molecular pump (pump is not included)

    Max withstand pressure for the standard flange included is 0.3 Mpa. Customization (up to 5 Mpa) is available at an extra cost

    Hydrogen Detector System

    Two Gas Detector is Integrated into the system. One is installed on the furnace to monitor potential gas leakage. The other one is portable which can be used to check other ports

    Working Temperature Range: -20ºC to +60ºC

    Detectable range: 1 - 1000 ppm

    Two-level Alarm Point:

    First level alarm point: once it reaches 50 ppm, the alarm is trigged

    Second level alarm point: once it reaches 100 ppm, it will shut off the inlet valve to the H2 automatically

    Gas-outlet Flow-meter

    One 1000 ml/min floating meter is installed on the gas-outlet end for adjusting gas flow rate

    1/4" Dia stainless steel tube is installed for burning hydrogen gas during gas flowing

    One long lighter is included in the standard package for igniting hydrogen gas manually

    One 6" long neck flexes safe lighter is included for lighting hydrogen gas

    Heating Element

    Fe-Cr-Al Alloy doped by Mo

    PC Connection

    RS485 port is installed in front of the panel for PC connection.

    PC control module and software are included for computerized temperature control

    The new version of PC module is now compatible with Lab View 05/08/2014

    Dimension

    1750mm L x 700mm W x 750 mm H

    Net Weight

    110 Kg

    Warranty

    One year limited warranty for electrical and mechanical parts
    Attention: A free course of safety operation training at field is required to purchase this furnace. A customer's side training is also available upon request at extra cost. If the users believe that they have sufficient experience and knowledge to handle the furnace in the dangerous or emergent situation, a liability release agreement must be signed at the purchase. HT is not responsible for any damages caused by misuse without the safety operation training. Any damages caused by the corrosive and acidic gases are not under the coverage of the One Year Limited Warranty.

    Warning

    Tube furnaces with alumina tubes are designed for use under vacuum and low pressure < 0.12 atm (absolute pressure)

    The flow rate for gases should be limited to < 200 SCCM for reducing thermal shocks to the tube

    Attention: A two-stage pressure regulator must be installed on gas cylinder to limit the pressure to below 3 PSI for safe operation. 

    Vacuum limit definition for all quartz tube furnaces: up to 1000°

     


    HTTF-1200-III-H2 Three Zone Tube Furnace is a safe hydrogen tube furnace. The processing tube is made of high-quality Ni-based superalloy which never cracks and is broken at flowing Hydrogen gas. Two hydrogen detectors are included which will shut down the Hydrogen gas generator and gas inlet valve immediately once detecting hydrogen gas leaking. The Hydrogen Gas tube furnace is designed for processing material under hydrogen gas up to 1200°C safely. The precision temperature controller is 30 segment programmable.

     

    Gas Furnace Structure

    Double layer steel casing with air cooling to keep furnace surface temperature lower than 80°C

    High purity fibrous alumina insulation for Max. energy saving

    Hydrogen detector and solenoid valve are included for safe operation

    4 alumina tube blocks (alumina coated on the surface) are included, to be put inside of the tube before operating the equipment in order to avoid heat radiation

    Power

    11 KW Max. (50A breaker required)

    Voltage

    AC 208-240 Single Phase, 50/60 Hz

    Working Temperature

    Furnace continuous temperature: 1400°C (Alumina tube must be used under this temperature)

    Tube Max. working temperature: 1250°C (< 0.5 hours, superalloy tube can't be used over this temperature)

    Tube continuous temperature: 1200°C (Quartz liner inside of the superalloy tube can't be used over this temperature)

    Max. Heating Rate

    10°C/min ( 5°C/min is recommended)

    Processing Tube

    Material: Nickel-based super-alloy seamless tube  ( Cr20NI25Al15

    Tube Size: OD 80mm x ID 72mm x Length 1200mm

    Temperature  1250°C, the tube can withstand pressure  0.1 Mpa

    Temperature  1200°C, the tube can withstand pressure  0.3 Mpa

    Temperature  1100°C, the tube can withstand pressure  1 Mpa

    Temperature  1000°C, the tube can withstand pressure  1.5 Mpa

    Temperature  900°C, the tube can withstand pressure  3 Mpa

    Temperature  800°C, the tube can withstand pressure  5 Mpa

    Heating Zone length

    Three-zone total length: 600mm

    Zone 1: 180mm, Zone 2: 180mm, Zone 3: 180mm

    Constant temperature zone: 260mm ± 3°C (set the same temperature for all 3 zones)

    Temperature controller

    PID automatic control with 30 segments programmable 

    Automatic over-temperature and thermal broken protection

    RS485 Communications Port

    Advanced Temperature Control (Optional)

    MTS02-Y Temperature control software kit (for YD518P series controllers) + 15" laptop package is available at the options bar.

    You may upgrade the controller to the Eurotherm 3004 with +/- 0.1 accuracy, which is compatible with LabVIEW. This package includes a Eurotherm 3004 programmer, and a communication cable (RS485 - USB).

    Flanges and Gas Inlet

    A set of SS304 flanges are included, KF-25 gas outlet port

    Vacuum level: 10-2 torr using a mechanical pump, 10-5 torr using a molecular pump (pump is not included)

    Max withstand pressure for the standard flange included is 0.3 Mpa. Customization (up to 5 Mpa) is available at an extra cost

    Hydrogen Detector System

    Two Gas Detector is Integrated into the system. One is installed on the furnace to monitor potential gas leakage. The other one is portable which can be used to check other ports

    Working Temperature Range: -20ºC to +60ºC

    Detectable range: 1 - 1000 ppm

    Two-level Alarm Point:

    First level alarm point: once it reaches 50 ppm, the alarm is trigged

    Second level alarm point: once it reaches 100 ppm, it will shut off the inlet valve to the H2 automatically

    Gas-outlet Flow-meter

    One 1000 ml/min floating meter is installed on the gas-outlet end for adjusting gas flow rate

    1/4" Dia stainless steel tube is installed for burning hydrogen gas during gas flowing

    One long lighter is included in the standard package for igniting hydrogen gas manually

    One 6" long neck flexes safe lighter is included for lighting hydrogen gas

    Heating Element

    Fe-Cr-Al Alloy doped by Mo

    PC Connection

    RS485 port is installed in front of the panel for PC connection.

    PC control module and software are included for computerized temperature control

    The new version of PC module is now compatible with Lab View 05/08/2014

    Dimension

    1750mm L x 700mm W x 750 mm H

    Net Weight

    110 Kg

    Warranty

    One year limited warranty for electrical and mechanical parts
    Attention: A free course of safety operation training at field is required to purchase this furnace. A customer's side training is also available upon request at extra cost. If the users believe that they have sufficient experience and knowledge to handle the furnace in the dangerous or emergent situation, a liability release agreement must be signed at the purchase. HT is not responsible for any damages caused by misuse without the safety operation training. Any damages caused by the corrosive and acidic gases are not under the coverage of the One Year Limited Warranty.

    Warning

    Tube furnaces with alumina tubes are designed for use under vacuum and low pressure < 0.12 atm (absolute pressure)

    The flow rate for gases should be limited to < 200 SCCM for reducing thermal shocks to the tube

    Attention: A two-stage pressure regulator must be installed on gas cylinder to limit the pressure to below 3 PSI for safe operation. 

    Vacuum limit definition for all quartz tube furnaces: up to 1000°