HTAF-1700-H Hybrid Hydrogen H2 Inert Gas Atmosphere Furnace with PC Control is a Hybrid box Hydrogen furnace for both of hydrogen treatment up to 1650 ºC. The H2 Gas Furnace furnace consists of high-quality alumina fiber bricks and Mo alloy heating elements. Gas Atmosphere Furnace is an ideal tool for preparing new materials that require Inert gas and reducing atmosphere.
Pledge: genuine guarantee,speed refund,gift insurance,seven days no reason to return
HTAF-1700-H Hybrid Hydrogen H2 Inert Gas Atmosphere Furnace with PC Control is a Hybrid box Hydrogen furnace for both of hydrogen treatment up to 1650 ºC. The H2 Gas Furnace furnace consists of high-quality alumina fiber bricks and Mo alloy heating elements with a heating chamber of 8 Liter, and an automatic H2 burning system. Gas Atmosphere Furnace is an ideal tool for preparing new materials that require Inert gas and reducing atmosphere.
SPECIFICATIONS of Hybrid Hydrogen H2 Inert Gas Atmosphere Furnace with PC Control
Furnace structure of gas furnace
| Double-layer steel structure for maximum vacuum and safety. Water cooling front door and air cooling shell Built-in pressure gauge, vacuum valves, and two gas float meters Built-in H2 burning control system --- if the controller detects no flame in the burner, the gas delivery valve will be shut down automatically Can be used as an inert gas furnace when closing H2 burning system. |
Heating Chamber size
| Heated chamber: 200x 200x 200 mm (8x8x8 inch), 8 Liter Max. Loading: 50 Kg |
Power | 7.5 KW |
Votage | AC 208 - 240V single phase (50/ 60 Hz) 30 Amp (50 Amp air breaker is required) |
Temperature of Hydrogen H2 Gas Furnace | Continuous 300 - 1600° C (Gas Atmosphere Furnace) Max. 1650° C(<60min) |
Heating Rate | 5°C / min |
Accuracy | +/- 0.1°C |
Thermocouple | two B type T/C for control and monitor alarm separately |
Heaing Elements Hydrogen Furnace | 6 sets of Mo coils heating elements are built-in and replaceable The heating element of the Mo coil is consumable parts which should be ordered separately if extra is required. Warning: Mo heating element cannot be used under air or oxygen at the temperature > 300°C |
Material of chamber | Energy-saving 1800 grade fibrous alumina insulation High purity Al2O3 coating Warning: One Al2O3 fibrous door block is included to block heat radiation. |
Control Panel of Hydrogen H2 Furnace | Built-in PC for controlling temperature and pressure (option) Temperature Control: controllers inside for +/- 1oC accuracy 30 segments programmable Protection for over-temperature and current, as well as the thermal couple, broke A secondary temperature controller is built-in for extra over-temperature protection. Pressure Control: The pressure sensor and pressure controller are installed to control setting pressure constant. The pressure control can be used to perform the following functions: Inert gas Purging via manually or an automatic mode Constand pressure during heating High and Low-pressure protection The pressure controllable range: -0.06 to 0.03Mpa. Safety Alarm System: Hydrogen H2 Gas Atmosphere Furnace Over-temperature protection Over-pressure and lower pressure alert Low water flow alert Data Collection (option): Recording temperature profile Recording pressure profile All data is saved to the hard disc of the PC Local WIFI operation at a remote distance is available upon request |
Gas Flow Control and Gas Purification (optional) | Two large flow meters (N2: 0~3.5L/min, H2: 0~3.5L/min) are installed on the front panel of the furnace. One heavy-duty vacuum pump ( CE/UL certified ) built-in bottom furnace to enhance the purging chamber. When using under inert gas, you may consider the optional gas purification below to keep gas purity below 1 PPM during heating at the extra cost. |
H2 Gas Burning Control System and Hydrogen detector (optional)
| An automatic ignition device is installed to ensure flowing He gas burning. If H2 does not burn properly, the controller will shut down the H2 gas delivery valve immediately. ( Pic. 1) Warning: You must install a certified Hydrogen detector in operation facility to alarm hydrogen leaking b accident. If you can not find it in a local store. |
Water Cooling (optional) | A 58L/min recirculating water colling is required to cool the furnace sealing flange and chamber case. If you don't have a water cooling system in your lab, you may click pictures below to order: |
Warranty of H2 Hydrogen Furnace
| One year limited warranty with lifetime support. (Consumable parts such as sample plates and heating elements are not covered by the warranty) |
Application Notes of Hybrid Hydrogen H2 Inert Gas Atmosphere Furnace with PC Control
Attention: A free course of safety operation training at HT field is required to purchase this H2 gas furnace. A customer's side training is also available upon request at extra cost. If the users believe that they have sufficient experience and knowledge to handle the H2 furnace in the dangerous or emergent situation, a liability release agreement must be signed at the purchase. HT Corp is not responsible for any damages caused by misuse without safety operation training. Any damages caused by the corrosive and acidic gases are not under the coverage of the HT One Year Limited Warranty.
HTAF-1700-H Hybrid Hydrogen H2 Inert Gas Atmosphere Furnace with PC Control is a Hybrid box Hydrogen furnace for both of hydrogen treatment up to 1650 ºC. The H2 Gas Furnace furnace consists of high-quality alumina fiber bricks and Mo alloy heating elements with a heating chamber of 8 Liter, and an automatic H2 burning system. Gas Atmosphere Furnace is an ideal tool for preparing new materials that require Inert gas and reducing atmosphere.
SPECIFICATIONS of Hybrid Hydrogen H2 Inert Gas Atmosphere Furnace with PC Control
Furnace structure of gas furnace
| Double-layer steel structure for maximum vacuum and safety. Water cooling front door and air cooling shell Built-in pressure gauge, vacuum valves, and two gas float meters Built-in H2 burning control system --- if the controller detects no flame in the burner, the gas delivery valve will be shut down automatically Can be used as an inert gas furnace when closing H2 burning system. |
Heating Chamber size
| Heated chamber: 200x 200x 200 mm (8x8x8 inch), 8 Liter Max. Loading: 50 Kg |
Power | 7.5 KW |
Votage | AC 208 - 240V single phase (50/ 60 Hz) 30 Amp (50 Amp air breaker is required) |
Temperature of Hydrogen H2 Gas Furnace | Continuous 300 - 1600° C (Gas Atmosphere Furnace) Max. 1650° C(<60min) |
Heating Rate | 5°C / min |
Accuracy | +/- 0.1°C |
Thermocouple | two B type T/C for control and monitor alarm separately |
Heaing Elements Hydrogen Furnace | 6 sets of Mo coils heating elements are built-in and replaceable The heating element of the Mo coil is consumable parts which should be ordered separately if extra is required. Warning: Mo heating element cannot be used under air or oxygen at the temperature > 300°C |
Material of chamber | Energy-saving 1800 grade fibrous alumina insulation High purity Al2O3 coating Warning: One Al2O3 fibrous door block is included to block heat radiation. |
Control Panel of Hydrogen H2 Furnace | Built-in PC for controlling temperature and pressure (option) Temperature Control: controllers inside for +/- 1oC accuracy 30 segments programmable Protection for over-temperature and current, as well as the thermal couple, broke A secondary temperature controller is built-in for extra over-temperature protection. Pressure Control: The pressure sensor and pressure controller are installed to control setting pressure constant. The pressure control can be used to perform the following functions: Inert gas Purging via manually or an automatic mode Constand pressure during heating High and Low-pressure protection The pressure controllable range: -0.06 to 0.03Mpa. Safety Alarm System: Hydrogen H2 Gas Atmosphere Furnace Over-temperature protection Over-pressure and lower pressure alert Low water flow alert Data Collection (option): Recording temperature profile Recording pressure profile All data is saved to the hard disc of the PC Local WIFI operation at a remote distance is available upon request |
Gas Flow Control and Gas Purification (optional) | Two large flow meters (N2: 0~3.5L/min, H2: 0~3.5L/min) are installed on the front panel of the furnace. One heavy-duty vacuum pump ( CE/UL certified ) built-in bottom furnace to enhance the purging chamber. When using under inert gas, you may consider the optional gas purification below to keep gas purity below 1 PPM during heating at the extra cost. |
H2 Gas Burning Control System and Hydrogen detector (optional)
| An automatic ignition device is installed to ensure flowing He gas burning. If H2 does not burn properly, the controller will shut down the H2 gas delivery valve immediately. ( Pic. 1) Warning: You must install a certified Hydrogen detector in operation facility to alarm hydrogen leaking b accident. If you can not find it in a local store. |
Water Cooling (optional) | A 58L/min recirculating water colling is required to cool the furnace sealing flange and chamber case. If you don't have a water cooling system in your lab, you may click pictures below to order: |
Warranty of H2 Hydrogen Furnace
| One year limited warranty with lifetime support. (Consumable parts such as sample plates and heating elements are not covered by the warranty) |
Application Notes of Hybrid Hydrogen H2 Inert Gas Atmosphere Furnace with PC Control
Attention: A free course of safety operation training at HT field is required to purchase this H2 gas furnace. A customer's side training is also available upon request at extra cost. If the users believe that they have sufficient experience and knowledge to handle the H2 furnace in the dangerous or emergent situation, a liability release agreement must be signed at the purchase. HT Corp is not responsible for any damages caused by misuse without safety operation training. Any damages caused by the corrosive and acidic gases are not under the coverage of the HT One Year Limited Warranty.